* Renesas H8/300 Timer Pluse Unit
|
||
|
|
||
|
The TPU is a 16bit timer/counter with configurable clock inputs and
|
||
|
programmable compare match.
|
||
|
This implementation support only cascade mode.
|
||
|
|
||
|
Required Properties:
|
||
|
|
||
|
- compatible: must contain "renesas,tpu"
|
||
|
- reg: base address and length of the registers block in 2 channel.
|
||
|
- clocks: a list of phandle, one for each entry in clock-names.
|
||
|
- clock-names: must contain "peripheral_clk" for the functional clock.
|
||
|
|
||
|
|
||
|
Example:
|
||
|
tpu: tpu@ffffe0 {
|
||
|
compatible = "renesas,tpu";
|
||
|
reg = <0xffffe0 16>, <0xfffff0 12>;
|
||
|
clocks = <&pclk>;
|
||
|
clock-names = "peripheral_clk";
|
||
|
};
|