Userspace thermal alert
|
||
|
=======================
|
||
|
|
||
|
Provides the facility for user space to know whether a thermal alert
|
||
|
occurred or not for temperature trip value. This is Supported by adding
|
||
|
a software thermal cooling device.
|
||
|
|
||
|
Features
|
||
|
--------
|
||
|
|
||
|
- Sends an "uevent" notification to user space on tripping the associated
|
||
|
thermal trip point.
|
||
|
"uevent" comes under /sys/class/thermal/cooling_device[0-*].
|
||
|
|
||
|
- sysfs API:
|
||
|
sysfs attributes are represented under
|
||
|
/sys/bus/platform/devices/userspace-alert.
|
||
|
|
||
|
Also a symlink to this is provide with
|
||
|
/sys/class/thermal/cooling_device[0-*]/userspace_alert.
|
||
|
|
||
|
/sys/bus/platform/devices/userspace-alert:
|
||
|
/sys/class/thermal/cooling_device[0-*]/userspace_alert:
|
||
|
|---thermal_alert_block
|
||
|
|---thermal_alert
|
||
|
|
||
|
thermal_alert_block
|
||
|
Read/Write value
|
||
|
|
||
|
Read: Blocks the read call until an alert occurs or the
|
||
|
specified duration times out. When alert occurs or if
|
||
|
alert is already present then read returns immediately
|
||
|
with value "1". If alert is not there and time out
|
||
|
happens then read returns with value "0".
|
||
|
|
||
|
Write: Set the time out duration(in milli seconds) to
|
||
|
wait when alert is not present. By default this value is
|
||
|
"0" if not set. Value of "0" wall wait for infinite
|
||
|
time. When alert occurs or if alert is already present,
|
||
|
then write value has no significance.
|
||
|
|
||
|
thermal_alert
|
||
|
Read only value
|
||
|
Read: If alert is present returns "1", otherwise
|
||
|
returns "0".
|
||
|
|
||
|
|
||
|
- The trip temperature can be modified at runtime if writable permission is
|
||
|
set in device tree properties of trip temperature.
|
||
|
If alert occurs then by increasing the trip temperature to value greater than
|
||
|
current temperature will make the alert to go off and user space can wait for
|
||
|
alert again with increased temperature trip.
|
||
|
For trip temperature sysfs, refer Documentation/thermal/sysfs-api.txt.
|
||
|
|
||
|
|
||
|
|
||
|
Note:
|
||
|
-----
|
||
|
This cooling device is intended with single trip temperature. When associated
|
||
|
with multiple trip points, alert will come for every trip temperature except
|
||
|
for the case when temperature goes to lower than the lowest trip temperature.
|
||
|
|