From 57fb9a40a02fcd09684e9b7077143f9a1f6ece31 Mon Sep 17 00:00:00 2001 From: Knutwurst <36196269+knutwurst@users.noreply.github.com> Date: Wed, 13 Jan 2021 14:21:05 +0100 Subject: [PATCH] Increase MAX_TEMP --- Marlin/Configuration.h | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index a36d9fa0..d30a97f6 100755 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -608,7 +608,7 @@ // Above this temperature the heater will be switched off. // This can protect components from overheating, but NOT from shorts and failures. // (Use MINTEMP for thermistor short/failure protection.) -#define HEATER_0_MAXTEMP 300 +#define HEATER_0_MAXTEMP 400 #define HEATER_1_MAXTEMP 275 #define HEATER_2_MAXTEMP 275 #define HEATER_3_MAXTEMP 275 @@ -616,7 +616,7 @@ #define HEATER_5_MAXTEMP 275 #define HEATER_6_MAXTEMP 275 #define HEATER_7_MAXTEMP 275 -#define BED_MAXTEMP 150 +#define BED_MAXTEMP 200 //=========================================================================== //============================= PID Settings ================================