Adjust temperature limits and margins
Lowering the safety margin of MAXTEMP to 10°C and raising MAXTEMP to 285/135. Resulting in a limit of 275°C for the hotend and 125°C for the heatbed. Referencing #23
This commit is contained in:
parent
94c99ff406
commit
28e86b95ed
|
@ -350,12 +350,12 @@
|
||||||
// When temperature exceeds max temp, your heater will be switched off.
|
// When temperature exceeds max temp, your heater will be switched off.
|
||||||
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
// This feature exists to protect your hotend from overheating accidentally, but *NOT* from thermistor short/failure!
|
||||||
// You should use MINTEMP for thermistor short/failure protection.
|
// You should use MINTEMP for thermistor short/failure protection.
|
||||||
#define HEATER_0_MAXTEMP 260
|
#define HEATER_0_MAXTEMP 285
|
||||||
#define HEATER_1_MAXTEMP 275
|
#define HEATER_1_MAXTEMP 275
|
||||||
#define HEATER_2_MAXTEMP 275
|
#define HEATER_2_MAXTEMP 275
|
||||||
#define HEATER_3_MAXTEMP 275
|
#define HEATER_3_MAXTEMP 275
|
||||||
#define HEATER_4_MAXTEMP 275
|
#define HEATER_4_MAXTEMP 275
|
||||||
#define BED_MAXTEMP 120
|
#define BED_MAXTEMP 135
|
||||||
|
|
||||||
//===========================================================================
|
//===========================================================================
|
||||||
//============================= PID Settings ================================
|
//============================= PID Settings ================================
|
||||||
|
|
|
@ -48,7 +48,7 @@
|
||||||
* here we define this default string as the date where the latest release
|
* here we define this default string as the date where the latest release
|
||||||
* version was tagged.
|
* version was tagged.
|
||||||
*/
|
*/
|
||||||
#define STRING_DISTRIBUTION_DATE "2019-02-06"
|
#define STRING_DISTRIBUTION_DATE "2019-02-11"
|
||||||
|
|
||||||
/**
|
/**
|
||||||
* Required minimum Configuration.h and Configuration_adv.h file versions.
|
* Required minimum Configuration.h and Configuration_adv.h file versions.
|
||||||
|
|
|
@ -308,7 +308,7 @@ uint8_t Temperature::soft_pwm_amount[HOTENDS];
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (target > GHV(BED_MAXTEMP, maxttemp[hotend]) - 15) {
|
if (target > GHV(BED_MAXTEMP, maxttemp[hotend]) - 10) {
|
||||||
SERIAL_ECHOLNPGM(MSG_PID_TEMP_TOO_HIGH);
|
SERIAL_ECHOLNPGM(MSG_PID_TEMP_TOO_HIGH);
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
|
|
|
@ -414,7 +414,7 @@ class Temperature {
|
||||||
#if ENABLED(AUTO_POWER_CONTROL)
|
#if ENABLED(AUTO_POWER_CONTROL)
|
||||||
powerManager.power_on();
|
powerManager.power_on();
|
||||||
#endif
|
#endif
|
||||||
target_temperature[HOTEND_INDEX] = MIN(celsius, maxttemp[HOTEND_INDEX] - 15);
|
target_temperature[HOTEND_INDEX] = MIN(celsius, maxttemp[HOTEND_INDEX] - 10);
|
||||||
#if WATCH_HOTENDS
|
#if WATCH_HOTENDS
|
||||||
start_watching_heater(HOTEND_INDEX);
|
start_watching_heater(HOTEND_INDEX);
|
||||||
#endif
|
#endif
|
||||||
|
@ -449,7 +449,7 @@ class Temperature {
|
||||||
#endif
|
#endif
|
||||||
target_temperature_bed =
|
target_temperature_bed =
|
||||||
#ifdef BED_MAXTEMP
|
#ifdef BED_MAXTEMP
|
||||||
MIN(celsius, BED_MAXTEMP - 15)
|
MIN(celsius, BED_MAXTEMP - 10)
|
||||||
#else
|
#else
|
||||||
celsius
|
celsius
|
||||||
#endif
|
#endif
|
||||||
|
|
Loading…