BLTouch 3.1 (#14839)
This commit is contained in:
parent
0b8b95bcc5
commit
6bc184df63
|
@ -477,14 +477,45 @@
|
|||
#endif
|
||||
#undef Z_SERVO_ANGLES
|
||||
#define Z_SERVO_ANGLES { BLTOUCH_DEPLOY, BLTOUCH_STOW }
|
||||
#define BLTOUCH_ANGLES { BLTOUCH_DEPLOY, BLTOUCH_STOW }
|
||||
|
||||
#define BLTOUCH_DEPLOY 10
|
||||
#define BLTOUCH_SW_MODE 60
|
||||
#define BLTOUCH_STOW 90
|
||||
#define BLTOUCH_SELFTEST 120
|
||||
#define BLTOUCH_MODE_STORE 130
|
||||
#define BLTOUCH_5V_MODE 140
|
||||
#define BLTOUCH_OD_MODE 150
|
||||
#define BLTOUCH_RESET 160
|
||||
|
||||
/**
|
||||
* The following commands require different minimum delays.
|
||||
*
|
||||
* 500ms required for a reliable Reset.
|
||||
*
|
||||
* 750ms required for Deploy/Stow, otherwise the alarm state
|
||||
* will not be seen until the following move command.
|
||||
*/
|
||||
|
||||
#ifndef BLTOUCH_SET5V_DELAY
|
||||
#define BLTOUCH_SET5V_DELAY 150
|
||||
#endif
|
||||
#ifndef BLTOUCH_SETOD_DELAY
|
||||
#define BLTOUCH_SETOD_DELAY 150
|
||||
#endif
|
||||
#ifndef BLTOUCH_MODE_STORE_DELAY
|
||||
#define BLTOUCH_MODE_STORE_DELAY 150
|
||||
#endif
|
||||
#ifndef BLTOUCH_DEPLOY_DELAY
|
||||
#define BLTOUCH_DEPLOY_DELAY 750
|
||||
#endif
|
||||
#ifndef BLTOUCH_STOW_DELAY
|
||||
#define BLTOUCH_STOW_DELAY 750
|
||||
#endif
|
||||
#ifndef BLTOUCH_RESET_DELAY
|
||||
#define BLTOUCH_RESET_DELAY 500
|
||||
#endif
|
||||
|
||||
#define BLTOUCH_DEPLOY 10
|
||||
#define BLTOUCH_SW_MODE 60
|
||||
#define BLTOUCH_STOW 90
|
||||
#define BLTOUCH_SELFTEST 120
|
||||
#define BLTOUCH_5V_MODE 140
|
||||
#define BLTOUCH_OD_MODE 150
|
||||
#define BLTOUCH_RESET 160
|
||||
#define _TEST_BLTOUCH(P) (READ(P##_PIN) != P##_ENDSTOP_INVERTING)
|
||||
|
||||
// Always disable probe pin inverting for BLTouch
|
||||
|
|
|
@ -734,20 +734,6 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
|
||||
/**
|
||||
* BLTouch V3.0 and newer smart series
|
||||
* For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV.
|
||||
* If the pin trigger is not detected, first try swapping the black and white wires then toggle this.
|
||||
*/
|
||||
//#define BLTOUCH_V3
|
||||
#if ENABLED(BLTOUCH_V3)
|
||||
//#define BLTOUCH_FORCE_5V_MODE
|
||||
//#define BLTOUCH_FORCE_OPEN_DRAIN_MODE
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -2079,50 +2079,240 @@ void clean_up_after_endstop_or_probe_move() {
|
|||
|
||||
#if ENABLED(BLTOUCH)
|
||||
|
||||
void bltouch_command(int angle) {
|
||||
MOVE_SERVO(Z_PROBE_SERVO_NR, angle); // Give the BL-Touch the command and wait
|
||||
safe_delay(BLTOUCH_DELAY);
|
||||
typedef unsigned char BLTCommand;
|
||||
void bltouch_init(const bool set_voltage=false);
|
||||
bool bltouch_last_written_mode; // Initialized by settings.load, 0 = Open Drain; 1 = 5V Drain
|
||||
|
||||
bool bltouch_triggered() {
|
||||
return (
|
||||
#if ENABLED(Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN)
|
||||
READ(Z_MIN_PIN) != Z_MIN_ENDSTOP_INVERTING
|
||||
#else
|
||||
READ(Z_MIN_PROBE_PIN) != Z_MIN_PROBE_ENDSTOP_INVERTING
|
||||
#endif
|
||||
);
|
||||
}
|
||||
|
||||
bool set_bltouch_deployed(const bool deploy) {
|
||||
if (deploy && TEST_BLTOUCH()) { // If BL-Touch says it's triggered
|
||||
bltouch_command(BLTOUCH_RESET); // try to reset it.
|
||||
bltouch_command(BLTOUCH_DEPLOY); // Also needs to deploy and stow to
|
||||
bltouch_command(BLTOUCH_STOW); // clear the triggered condition.
|
||||
safe_delay(1500); // Wait for internal self-test to complete.
|
||||
// (Measured completion time was 0.65 seconds
|
||||
// after reset, deploy, and stow sequence)
|
||||
if (TEST_BLTOUCH()) { // If it still claims to be triggered...
|
||||
SERIAL_ERROR_START();
|
||||
SERIAL_ERRORLNPGM(MSG_STOP_BLTOUCH);
|
||||
stop(); // punt!
|
||||
return true;
|
||||
bool bltouch_command(const BLTCommand cmd, const millis_t &ms) {
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPAIR("BLTouch Command :", cmd);
|
||||
#endif
|
||||
MOVE_SERVO(Z_PROBE_SERVO_NR, cmd);
|
||||
safe_delay(MAX(ms, (uint32_t)BLTOUCH_DELAY)); // BLTOUCH_DELAY is also the *minimum* delay
|
||||
return bltouch_triggered();
|
||||
}
|
||||
|
||||
// Native BLTouch commands ("Underscore"...), used in lcd menus and internally
|
||||
void _bltouch_reset() { bltouch_command(BLTOUCH_RESET, BLTOUCH_RESET_DELAY); }
|
||||
|
||||
void _bltouch_selftest() { bltouch_command(BLTOUCH_SELFTEST, BLTOUCH_DELAY); }
|
||||
|
||||
void _bltouch_set_SW_mode() { bltouch_command(BLTOUCH_SW_MODE, BLTOUCH_DELAY); }
|
||||
|
||||
void _bltouch_set_5V_mode() { bltouch_command(BLTOUCH_5V_MODE, BLTOUCH_SET5V_DELAY); }
|
||||
void _bltouch_set_OD_mode() { bltouch_command(BLTOUCH_OD_MODE, BLTOUCH_SETOD_DELAY); }
|
||||
void _bltouch_mode_store() { bltouch_command(BLTOUCH_MODE_STORE, BLTOUCH_MODE_STORE_DELAY); }
|
||||
|
||||
void _bltouch_deploy() { bltouch_command(BLTOUCH_DEPLOY, BLTOUCH_DEPLOY_DELAY); }
|
||||
void _bltouch_stow() { bltouch_command(BLTOUCH_STOW, BLTOUCH_STOW_DELAY); }
|
||||
|
||||
void _bltouch_reset_SW_mode() { if (bltouch_triggered()) _bltouch_stow(); else _bltouch_deploy(); }
|
||||
|
||||
bool _bltouch_deploy_query_alarm() { return bltouch_command(BLTOUCH_DEPLOY, BLTOUCH_DEPLOY_DELAY); }
|
||||
bool _bltouch_stow_query_alarm() { return bltouch_command(BLTOUCH_STOW, BLTOUCH_STOW_DELAY); }
|
||||
|
||||
void bltouch_clear() {
|
||||
_bltouch_reset(); // RESET or RESET_SW will clear an alarm condition but...
|
||||
// ...it will not clear a triggered condition in SW mode when the pin is currently up
|
||||
// ANTClabs <-- CODE ERROR
|
||||
_bltouch_stow(); // STOW will pull up the pin and clear any triggered condition unless it fails, don't care
|
||||
_bltouch_deploy(); // DEPLOY to test the probe. Could fail, don't care
|
||||
_bltouch_stow(); // STOW to be ready for meaningful work. Could fail, don't care
|
||||
}
|
||||
|
||||
bool bltouch_deploy_proc() {
|
||||
// Do a DEPLOY
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch DEPLOY requested");
|
||||
#endif
|
||||
|
||||
// Attempt to DEPLOY, wait for DEPLOY_DELAY or ALARM
|
||||
if (_bltouch_deploy_query_alarm()) {
|
||||
// The deploy might have failed or the probe is already triggered (nozzle too low?)
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch ALARM or TRIGGER after DEPLOY, recovering");
|
||||
#endif
|
||||
|
||||
bltouch_clear(); // Get the probe into start condition
|
||||
|
||||
// Last attempt to DEPLOY
|
||||
if (_bltouch_deploy_query_alarm()) {
|
||||
// The deploy might have failed or the probe is actually triggered (nozzle too low?) again
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch Recovery Failed");
|
||||
#endif
|
||||
|
||||
SERIAL_ECHOLN(MSG_STOP_BLTOUCH); // Tell the user something is wrong, needs action
|
||||
stop(); // but it's not too bad, no need to kill, allow restart
|
||||
|
||||
return true; // Tell our caller we goofed in case he cares to know
|
||||
}
|
||||
}
|
||||
|
||||
#if ENABLED(BLTOUCH_FORCE_5V_MODE)
|
||||
bltouch_command(BLTOUCH_5V_MODE);
|
||||
#elif ENABLED(BLTOUCH_V3)
|
||||
bltouch_command(BLTOUCH_OD_MODE);
|
||||
// One of the recommended ANTClabs ways to probe, using SW MODE
|
||||
#if ENABLED(BLTOUCH_FORCE_SW_MODE)
|
||||
_bltouch_set_SW_mode();
|
||||
#endif
|
||||
|
||||
bltouch_command(deploy ? BLTOUCH_DEPLOY : BLTOUCH_STOW);
|
||||
|
||||
#if ENABLED(BLTOUCH_V3)
|
||||
if (deploy) bltouch_command(BLTOUCH_SW_MODE);
|
||||
// Now the probe is ready to issue a 10ms pulse when the pin goes up.
|
||||
// The trigger STOW (see motion.cpp for example) will pull up the probes pin as soon as the pulse
|
||||
// is registered.
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("bltouch.deploy_proc() end");
|
||||
#endif
|
||||
|
||||
return false; // report success to caller
|
||||
}
|
||||
|
||||
bool bltouch_stow_proc() {
|
||||
// Do a STOW
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch STOW requested");
|
||||
#endif
|
||||
|
||||
// A STOW will clear a triggered condition in the probe (10ms pulse).
|
||||
// At the moment that we come in here, we might (pulse) or will (SW mode) see the trigger on the pin.
|
||||
// So even though we know a STOW will be ignored if an ALARM condition is active, we will STOW.
|
||||
// Note: If the probe is deployed AND in an ALARM condition, this STOW will not pull up the pin
|
||||
// and the ALARM condition will still be there. --> ANTClabs should change this behavior maybe
|
||||
|
||||
// Attempt to STOW, wait for STOW_DELAY or ALARM
|
||||
if (_bltouch_stow_query_alarm()) {
|
||||
// The stow might have failed
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch ALARM or TRIGGER after STOW, recovering");
|
||||
#endif
|
||||
|
||||
_bltouch_reset(); // This RESET will then also pull up the pin. If it doesn't
|
||||
// work and the pin is still down, there will no longer be
|
||||
// an ALARM condition though.
|
||||
// But one more STOW will catch that
|
||||
// Last attempt to STOW
|
||||
if (_bltouch_stow_query_alarm()) { // so if there is now STILL an ALARM condition:
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch Recovery Failed");
|
||||
#endif
|
||||
|
||||
SERIAL_ECHOLN(MSG_STOP_BLTOUCH); // Tell the user something is wrong, needs action
|
||||
stop(); // but it's not too bad, no need to kill, allow restart
|
||||
|
||||
return true; // Tell our caller we goofed in case he cares to know
|
||||
}
|
||||
}
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) {
|
||||
SERIAL_ECHOPAIR("set_bltouch_deployed(", deploy);
|
||||
SERIAL_CHAR(')');
|
||||
SERIAL_EOL();
|
||||
}
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("bltouch.stow_proc() end");
|
||||
#endif
|
||||
|
||||
return false; // report success to caller
|
||||
}
|
||||
|
||||
bool bltouch_status_proc() {
|
||||
/**
|
||||
* Return a TRUE for "YES, it is DEPLOYED"
|
||||
* This function will ensure switch state is reset after execution
|
||||
*/
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPGM("BLTouch STATUS requested");
|
||||
#endif
|
||||
|
||||
_bltouch_set_SW_mode(); // Incidentally, _set_SW_mode() will also RESET any active alarm
|
||||
const bool tr = bltouch_triggered(); // If triggered in SW mode, the pin is up, it is STOWED
|
||||
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPAIR("BLTouch is ", (int)tr);
|
||||
#endif
|
||||
|
||||
if (tr) _bltouch_stow(); else _bltouch_deploy(); // Turn off SW mode, reset any trigger, honor pin state
|
||||
return !tr;
|
||||
}
|
||||
|
||||
void bltouch_mode_conv_proc(const bool M5V) {
|
||||
/**
|
||||
* BLTOUCH pre V3.0 and clones: No reaction at all to this sequence apart from a DEPLOY -> STOW
|
||||
* BLTOUCH V3.0: This will set the mode (twice) and sadly, a STOW is needed at the end, because of the deploy
|
||||
* BLTOUCH V3.1: This will set the mode and store it in the eeprom. The STOW is not needed but does not hurt
|
||||
*/
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) SERIAL_ECHOLNPAIR("BLTouch Set Mode - ", (int)M5V);
|
||||
#endif
|
||||
_bltouch_deploy();
|
||||
if (M5V) _bltouch_set_5V_mode(); else _bltouch_set_OD_mode();
|
||||
_bltouch_mode_store();
|
||||
if (M5V) _bltouch_set_5V_mode(); else _bltouch_set_OD_mode();
|
||||
_bltouch_stow();
|
||||
bltouch_last_written_mode = M5V;
|
||||
}
|
||||
|
||||
bool set_bltouch_deployed(const bool deploy) {
|
||||
if (deploy) _bltouch_deploy(); else _bltouch_stow();
|
||||
return false;
|
||||
}
|
||||
|
||||
void bltouch_mode_conv_5V() { bltouch_mode_conv_proc(true); }
|
||||
void bltouch_mode_conv_OD() { bltouch_mode_conv_proc(false); }
|
||||
|
||||
// DEPLOY and STOW are wrapped for error handling - these are used by homing and by probing
|
||||
bool bltouch_deploy() { return bltouch_deploy_proc(); }
|
||||
bool bltouch_stow() { return bltouch_stow_proc(); }
|
||||
bool bltouch_status() { return bltouch_status_proc(); }
|
||||
|
||||
// Init the class and device. Call from setup().
|
||||
void bltouch_init(const bool set_voltage/*=false*/) {
|
||||
// Voltage Setting (if enabled). At every Marlin initialization:
|
||||
// BLTOUCH < V3.0 and clones: This will be ignored by the probe
|
||||
// BLTOUCH V3.0: SET_5V_MODE or SET_OD_MODE (if enabled).
|
||||
// OD_MODE is the default on power on, but setting it does not hurt
|
||||
// This mode will stay active until manual SET_OD_MODE or power cycle
|
||||
// BLTOUCH V3.1: SET_5V_MODE or SET_OD_MODE (if enabled).
|
||||
// At power on, the probe will default to the eeprom settings configured by the user
|
||||
_bltouch_reset();
|
||||
_bltouch_stow();
|
||||
|
||||
#if ENABLED(BLTOUCH_FORCE_MODE_SET)
|
||||
|
||||
constexpr bool should_set = true;
|
||||
|
||||
#else
|
||||
#if ENABLED(DEBUG_LEVELING_FEATURE)
|
||||
if (DEBUGGING(LEVELING)) {
|
||||
SERIAL_ECHOLNPAIR("last_written_mode - ", int(bltouch_last_written_mode));
|
||||
SERIAL_ECHOLNPGM("config mode - "
|
||||
#if ENABLED(BLTOUCH_SET_5V_MODE)
|
||||
"BLTOUCH_SET_5V_MODE"
|
||||
#else
|
||||
"OD"
|
||||
#endif
|
||||
);
|
||||
}
|
||||
#endif
|
||||
|
||||
const bool should_set = bltouch_last_written_mode != (false
|
||||
#if ENABLED(BLTOUCH_SET_5V_MODE)
|
||||
|| true
|
||||
#endif
|
||||
);
|
||||
|
||||
#endif
|
||||
|
||||
if (should_set && set_voltage)
|
||||
bltouch_mode_conv_proc((false
|
||||
#if ENABLED(BLTOUCH_SET_5V_MODE)
|
||||
|| true
|
||||
#endif
|
||||
));
|
||||
}
|
||||
#endif // BLTOUCH
|
||||
|
||||
/**
|
||||
|
@ -4274,7 +4464,7 @@ inline void gcode_G28(const bool always_home_all) {
|
|||
|
||||
#if ENABLED(BLTOUCH)
|
||||
// Make sure any BLTouch error condition is cleared
|
||||
bltouch_command(BLTOUCH_RESET);
|
||||
bltouch_command(BLTOUCH_RESET, BLTOUCH_RESET_DELAY);
|
||||
set_bltouch_deployed(false);
|
||||
#endif
|
||||
|
||||
|
@ -15419,7 +15609,7 @@ void setup() {
|
|||
|
||||
#if ENABLED(BLTOUCH)
|
||||
// Make sure any BLTouch error condition is cleared
|
||||
bltouch_command(BLTOUCH_RESET);
|
||||
bltouch_command(BLTOUCH_RESET, BLTOUCH_RESET_DELAY);
|
||||
set_bltouch_deployed(false);
|
||||
#endif
|
||||
|
||||
|
|
|
@ -37,7 +37,7 @@
|
|||
*/
|
||||
|
||||
// Change EEPROM version if the structure changes
|
||||
#define EEPROM_VERSION "V55"
|
||||
#define EEPROM_VERSION "V56"
|
||||
#define EEPROM_OFFSET 100
|
||||
|
||||
// Check the integrity of data offsets.
|
||||
|
@ -77,6 +77,10 @@
|
|||
#define LPQ_LEN thermalManager.lpq_len
|
||||
#endif
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
extern bool bltouch_last_written_mode;
|
||||
#endif
|
||||
|
||||
#pragma pack(push, 1) // No padding between variables
|
||||
|
||||
typedef struct PID { float Kp, Ki, Kd; } PID;
|
||||
|
@ -159,6 +163,11 @@ typedef struct SettingsDataStruct {
|
|||
bool planner_leveling_active; // M420 S planner.leveling_active
|
||||
int8_t ubl_storage_slot; // ubl.storage_slot
|
||||
|
||||
//
|
||||
// BLTOUCH
|
||||
//
|
||||
bool bltouch_last_written_mode;
|
||||
|
||||
//
|
||||
// DELTA / [XYZ]_DUAL_ENDSTOPS
|
||||
//
|
||||
|
@ -572,6 +581,20 @@ void MarlinSettings::postprocess() {
|
|||
EEPROM_WRITE(storage_slot);
|
||||
#endif // AUTO_BED_LEVELING_UBL
|
||||
|
||||
//
|
||||
// BLTOUCH
|
||||
//
|
||||
{
|
||||
_FIELD_TEST(bltouch_last_written_mode);
|
||||
#if ENABLED(BLTOUCH)
|
||||
const bool &eeprom_bltouch_last_written_mode = bltouch_last_written_mode;
|
||||
#else
|
||||
constexpr bool eeprom_bltouch_last_written_mode = false;
|
||||
#endif
|
||||
EEPROM_WRITE(eeprom_bltouch_last_written_mode);
|
||||
}
|
||||
|
||||
|
||||
// 11 floats for DELTA / [XYZ]_DUAL_ENDSTOPS
|
||||
#if ENABLED(DELTA)
|
||||
|
||||
|
@ -1190,6 +1213,19 @@ void MarlinSettings::postprocess() {
|
|||
EEPROM_READ(dummyui8);
|
||||
#endif // AUTO_BED_LEVELING_UBL
|
||||
|
||||
//
|
||||
// BLTOUCH
|
||||
//
|
||||
{
|
||||
_FIELD_TEST(bltouch_last_written_mode);
|
||||
#if ENABLED(BLTOUCH)
|
||||
bool &eeprom_bltouch_last_written_mode = bltouch_last_written_mode;
|
||||
#else
|
||||
bool eeprom_bltouch_last_written_mode;
|
||||
#endif
|
||||
EEPROM_READ(eeprom_bltouch_last_written_mode);
|
||||
}
|
||||
|
||||
//
|
||||
// DELTA Geometry or Dual Endstops offsets
|
||||
//
|
||||
|
|
|
@ -316,6 +316,10 @@ static void print_es_state(const bool is_hit, const char * const label=NULL) {
|
|||
}
|
||||
|
||||
void _O2 Endstops::M119() {
|
||||
#if ENABLED(BLTOUCH)
|
||||
extern void _bltouch_set_SW_mode();
|
||||
_bltouch_set_SW_mode();
|
||||
#endif
|
||||
SERIAL_PROTOCOLLNPGM(MSG_M119_REPORT);
|
||||
#define ES_REPORT(S) print_es_state(READ(S##_PIN) != S##_ENDSTOP_INVERTING, PSTR(MSG_##S))
|
||||
#if HAS_X_MIN
|
||||
|
@ -383,6 +387,10 @@ void _O2 Endstops::M119() {
|
|||
}
|
||||
#endif
|
||||
#endif
|
||||
#if ENABLED(BLTOUCH)
|
||||
extern void _bltouch_reset_SW_mode();
|
||||
_bltouch_reset_SW_mode();
|
||||
#endif
|
||||
} // Endstops::M119
|
||||
|
||||
// The following routines are called from an ISR context. It could be the temperature ISR, the
|
||||
|
|
|
@ -741,9 +741,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -760,9 +760,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -769,9 +769,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -734,9 +734,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -736,9 +736,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -734,9 +734,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
#define BLTOUCH_DELAY 100 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
#define BLTOUCH_DELAY 100
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -649,9 +649,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -709,9 +709,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -722,9 +722,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -709,9 +709,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -720,9 +720,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -731,9 +731,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -740,9 +740,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -731,9 +731,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -731,9 +731,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -703,9 +703,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -703,9 +703,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -727,9 +727,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -736,9 +736,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -723,6 +723,17 @@
|
|||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
|
||||
/**
|
||||
* BLTouch V3.0 and newer smart series
|
||||
* For genuine BLTouch 3.0 sensors. Clones may be confused by 3.0 command angles. YMMV.
|
||||
* If the pin trigger is not detected, first try swapping the black and white wires then toggle this.
|
||||
*/
|
||||
//#define BLTOUCH_V3
|
||||
#if ENABLED(BLTOUCH_V3)
|
||||
//#define BLTOUCH_FORCE_5V_MODE
|
||||
//#define BLTOUCH_FORCE_OPEN_DRAIN_MODE
|
||||
#endif
|
||||
#endif
|
||||
|
||||
/**
|
||||
|
|
|
@ -737,9 +737,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -736,9 +736,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -733,9 +733,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -741,9 +741,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -725,9 +725,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -761,9 +761,7 @@ Black rubber belt(MXL), 18 - tooth aluminium pulley : 87.489 step per mm (Huxley
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -719,9 +719,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -734,9 +734,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -752,9 +752,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -772,9 +772,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -732,9 +732,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -750,9 +750,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -397,6 +397,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -731,9 +731,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -721,9 +721,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -860,9 +860,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -806,9 +806,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -806,9 +806,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -806,9 +806,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|
|
@ -394,6 +394,65 @@
|
|||
// Enable this if X or Y can't home without homing the other axis first.
|
||||
//#define CODEPENDENT_XY_HOMING
|
||||
|
||||
#if ENABLED(BLTOUCH)
|
||||
/**
|
||||
* Either: Use the defaults (recommended) or: For special purposes, use the following DEFINES
|
||||
* Do not activate settings that the probe might not understand. Clones might misunderstand
|
||||
* advanced commands.
|
||||
*
|
||||
* Note: If the probe is not deploying, check a "Cmd: Reset" and "Cmd: Self-Test" and then
|
||||
* check the wiring of the BROWN, RED and ORANGE wires.
|
||||
*
|
||||
* Note: If the trigger signal of your probe is not being recognized, it has been very often
|
||||
* because the BLACK and WHITE wires needed to be swapped. They are not "interchangeable"
|
||||
* like they would be with a real switch. So please check the wiring first.
|
||||
*
|
||||
* Settings for all BLTouch and clone probes:
|
||||
*/
|
||||
|
||||
// Safety: The probe needs time to recognize the command.
|
||||
// Minimum command delay (ms). Enable and increase if needed.
|
||||
//#define BLTOUCH_DELAY 500
|
||||
|
||||
/**
|
||||
* Settings for BLTOUCH Classic 1.2, 1.3 or BLTouch Smart 1.0, 2.0, 2.2, 3.0, 3.1, and most clones:
|
||||
*/
|
||||
|
||||
// Feature: Switch into SW mode after a deploy. It makes the output pulse longer. Can be useful
|
||||
// in special cases, like noisy or filtered input configurations.
|
||||
//#define BLTOUCH_FORCE_SW_MODE
|
||||
|
||||
/**
|
||||
* Settings for BLTouch Smart 3.0 and 3.1
|
||||
* Summary:
|
||||
* - Voltage modes: 5V and OD (open drain - "logic voltage free") output modes
|
||||
* - High-Speed mode
|
||||
* - Disable LCD voltage options
|
||||
*/
|
||||
|
||||
/**
|
||||
* Danger: Don't activate 5V mode unless attached to a 5V-tolerant controller!
|
||||
* V3.0 or 3.1: Set default mode to 5V mode at Marlin startup.
|
||||
* If disabled, OD mode is the hard-coded default on 3.0
|
||||
* On startup, Marlin will compare its eeprom to this vale. If the selected mode
|
||||
* differs, a mode set eeprom write will be completed at initialization.
|
||||
* Use the option below to force an eeprom write to a V3.1 probe regardless.
|
||||
*/
|
||||
//#define BLTOUCH_SET_5V_MODE
|
||||
|
||||
/**
|
||||
* Safety: Activate if connecting a probe with an unknown voltage mode.
|
||||
* V3.0: Set a probe into mode selected above at Marlin startup. Required for 5V mode on 3.0
|
||||
* V3.1: Force a probe with unknown mode into selected mode at Marlin startup ( = Probe EEPROM write )
|
||||
* To preserve the life of the probe, use this once then turn it off and re-flash.
|
||||
*/
|
||||
//#define BLTOUCH_FORCE_MODE_SET
|
||||
|
||||
// Safety: Enable voltage mode settings in the LCD menu.
|
||||
//#define BLTOUCH_LCD_VOLTAGE_MENU
|
||||
|
||||
#endif // BLTOUCH
|
||||
|
||||
// @section machine
|
||||
|
||||
#define AXIS_RELATIVE_MODES {false, false, false, false}
|
||||
|
|
|
@ -811,9 +811,7 @@
|
|||
* The BLTouch probe uses a Hall effect sensor and emulates a servo.
|
||||
*/
|
||||
//#define BLTOUCH
|
||||
#if ENABLED(BLTOUCH)
|
||||
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
|
||||
#endif
|
||||
|
||||
|
||||
/**
|
||||
* Enable one or more of the following if probing seems unreliable.
|
||||
|
|