From 7f311c086ee68d9222015227283ceef0b4101a9c Mon Sep 17 00:00:00 2001 From: David Ramiro Date: Thu, 13 Dec 2018 10:03:25 +0100 Subject: [PATCH] Edit default values Getting closer to the stock settings, I edited the hotend PID and extruder step values. --- Marlin/Configuration.h | 8 ++++---- Marlin/Version.h | 2 +- README.md | 3 +-- 3 files changed, 6 insertions(+), 7 deletions(-) diff --git a/Marlin/Configuration.h b/Marlin/Configuration.h index 181656c..be7d602 100644 --- a/Marlin/Configuration.h +++ b/Marlin/Configuration.h @@ -380,8 +380,8 @@ // If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it // i3 Mega - #define DEFAULT_Kp 13.76 - #define DEFAULT_Ki 0.85 + #define DEFAULT_Kp 16.43 + #define DEFAULT_Ki 1.03 #define DEFAULT_Kd 55.79 // Ultimaker @@ -612,7 +612,7 @@ * Override with M92 * X, Y, Z, E0 [, E1[, E2[, E3[, E4]]]] */ -#define DEFAULT_AXIS_STEPS_PER_UNIT { 80, 80, 400, 98.26 } +#define DEFAULT_AXIS_STEPS_PER_UNIT { 80, 80, 400, 92.6 } /** * Default Max Feed Rate (mm/s) @@ -1015,7 +1015,7 @@ #if ENABLED(G26_MESH_VALIDATION) #define MESH_TEST_NOZZLE_SIZE 0.4 // (mm) Diameter of primary nozzle. #define MESH_TEST_LAYER_HEIGHT 0.2 // (mm) Default layer height for the G26 Mesh Validation Tool. - #define MESH_TEST_HOTEND_TEMP 205.0 // (°C) Default nozzle temperature for the G26 Mesh Validation Tool. + #define MESH_TEST_HOTEND_TEMP 200.0 // (°C) Default nozzle temperature for the G26 Mesh Validation Tool. #define MESH_TEST_BED_TEMP 60.0 // (°C) Default bed temperature for the G26 Mesh Validation Tool. #endif diff --git a/Marlin/Version.h b/Marlin/Version.h index 3e17cde..c213e06 100644 --- a/Marlin/Version.h +++ b/Marlin/Version.h @@ -48,7 +48,7 @@ * here we define this default string as the date where the latest release * version was tagged. */ - #define STRING_DISTRIBUTION_DATE "2019-12-02" + #define STRING_DISTRIBUTION_DATE "2018-12-13" /** * Required minimum Configuration.h and Configuration_adv.h file versions. diff --git a/README.md b/README.md index 971d945..6d16d2e 100644 --- a/README.md +++ b/README.md @@ -61,7 +61,7 @@ This firmware is perfectly calibrated for my own machine with TMC2208 (1.015V on - If it's less or more than 20mm, add or subtract that value from 100mm, e.g.: - If you measure 25mm, your result would be 95mm. If you measure 15mm, your result would be 105mm - Calculate your new value: ( 100mm / actually extruded filament ) * 98.26 -- For example, if your markings are at 15mm, you'd calculate: (100/105) * 98.26 = 93.58 +- For example, if your markings are at 15mm, you'd calculate: (100/105) * 92.6 = 88.19 - Put in the new value like this: `M92 X80.00 Y80.00 Z400.00 Exxx.xx`, replacing `x` with your value - Save with `M500` @@ -99,7 +99,6 @@ M420 S1 ## Detailed changes: - Thermal runaway protection enabled -- TMC2208 configured in standalone mode - Stepper orientation flipped (you don't have to flip the connectors on the board anymore) - Linear advance enabled (Off by default. [Research, calibrate](http://marlinfw.org/docs/features/lin_advance.html) and then enable with `M900 Kx`) - S-Curve Acceleration enabled