Raise PWM frequency
Adjusting PWM frequencies to better match FDD8780 MOSFET spec. - Hotend PWM frequency increased from 488.28 Hz to 1953.12 Hz – Referencing the Forward Bias Safe Area from the hotend MOSFET's datasheet, this value should be safer. - Hotbed PWM frequency increased from 7.26Hz to 30.48Hz - Use software PWM for fans to reduce whine – The higher PWM frequency works well with the stock parts cooling fan and might allow for better control of third party fans
This commit is contained in:
		| @@ -379,10 +379,10 @@ | ||||
|  | ||||
|   // If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it | ||||
|  | ||||
|   // i3 Mega | ||||
|   #define  DEFAULT_Kp 15.94 | ||||
|   #define  DEFAULT_Ki 1.17 | ||||
|   #define  DEFAULT_Kd 54.19 | ||||
|   // i3 Mega stock v5 hotend, 40W heater cartridge (3.6Ω @ 22°C) | ||||
|   #define  DEFAULT_Kp 18.58 | ||||
|   #define  DEFAULT_Ki 1.38 | ||||
|   #define  DEFAULT_Kd 62.40 | ||||
|  | ||||
|   // Ultimaker | ||||
|   //#define  DEFAULT_Kp 22.2 | ||||
| @@ -436,10 +436,10 @@ | ||||
|  | ||||
|   //#define PID_BED_DEBUG // Sends debug data to the serial port. | ||||
|  | ||||
|   //Anycubic i3 Mega 160W Ultrabase | ||||
|   #define DEFAULT_bedKp 251.78 | ||||
|   #define DEFAULT_bedKi 49.57 | ||||
|   #define DEFAULT_bedKd 319.73 | ||||
|   //Anycubic i3 Mega Ultrabase (0.9Ω @ 22°C) | ||||
|   #define DEFAULT_bedKp 187.45 | ||||
|   #define DEFAULT_bedKi 35.75 | ||||
|   #define DEFAULT_bedKd 245.71 | ||||
|  | ||||
|   //120V 250W silicone heater into 4mm borosilicate (MendelMax 1.5+) | ||||
|   //from pidautotune | ||||
| @@ -1827,13 +1827,13 @@ | ||||
| // Use software PWM to drive the fan, as for the heaters. This uses a very low frequency | ||||
| // which is not as annoying as with the hardware PWM. On the other hand, if this frequency | ||||
| // is too low, you should also increment SOFT_PWM_SCALE. | ||||
| //#define FAN_SOFT_PWM | ||||
| #define FAN_SOFT_PWM | ||||
|  | ||||
| // Incrementing this by 1 will double the software PWM frequency, | ||||
| // affecting heaters, and the fan if FAN_SOFT_PWM is enabled. | ||||
| // However, control resolution will be halved for each increment; | ||||
| // at zero value, there are 128 effective control positions. | ||||
| #define SOFT_PWM_SCALE 0 | ||||
| #define SOFT_PWM_SCALE 2 | ||||
|  | ||||
| // If SOFT_PWM_SCALE is set to a value higher than 0, dithering can | ||||
| // be used to mitigate the associated resolution loss. If enabled, | ||||
|   | ||||
		Reference in New Issue
	
	Block a user