Less aggressive thermal runaway protection

This commit is contained in:
Knutwurst
2020-10-10 11:56:57 +02:00
parent db0c96be7a
commit 5c10986c6b
2 changed files with 33 additions and 33 deletions

View File

@@ -152,7 +152,7 @@
* THERMAL_PROTECTION_HYSTERESIS and/or THERMAL_PROTECTION_PERIOD
*/
#if ENABLED(THERMAL_PROTECTION_HOTENDS)
#define THERMAL_PROTECTION_PERIOD 3 // Seconds
#define THERMAL_PROTECTION_PERIOD 10 // Seconds
#define THERMAL_PROTECTION_HYSTERESIS 15 // Degrees Celsius
//#define ADAPTIVE_FAN_SLOWING // Slow part cooling fan if temperature drops
@@ -172,8 +172,8 @@
* and/or decrease WATCH_TEMP_INCREASE. WATCH_TEMP_INCREASE should not be set
* below 2.
*/
#define WATCH_TEMP_PERIOD 35 // Seconds
#define WATCH_TEMP_INCREASE 5 // Degrees Celsius
#define WATCH_TEMP_PERIOD 30 // Seconds
#define WATCH_TEMP_INCREASE 3 // Degrees Celsius
#endif
/**