lower the maximum hotend temperature to stay within the thermistor range

The default thermistor type 1 supports a maximum value of 300°C. The
maximum heater temperature plus overshoot value must stay within that
range. For all targets but 4MAXP2 we use type 1 with a default overshoot
value of 15°C, so let's lower the maximum heater temperature to 285.
This commit is contained in:
Stefan Kalscheuer
2023-05-28 17:17:57 +02:00
parent f92a587638
commit bdd6e0c7fe

View File

@@ -740,7 +740,11 @@
// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
// (Use MINTEMP for thermistor short/failure protection.)
#define HEATER_0_MAXTEMP 300
#if ENABLED(KNUTWURST_4MAXP2)
#define HEATER_0_MAXTEMP 300
#else
#define HEATER_0_MAXTEMP 285
#endif
#define HEATER_1_MAXTEMP 275
#define HEATER_2_MAXTEMP 275
#define HEATER_3_MAXTEMP 275