Stefan Kalscheuer bdd6e0c7fe lower the maximum hotend temperature to stay within the thermistor range
The default thermistor type 1 supports a maximum value of 300°C. The
maximum heater temperature plus overshoot value must stay within that
range. For all targets but 4MAXP2 we use type 1 with a default overshoot
value of 15°C, so let's lower the maximum heater temperature to 285.