Increase maximum hotend target temperature to 300 degrees instead of 260.

This commit is contained in:
Knutwurst
2021-06-21 22:33:26 +02:00
parent 035538dac7
commit fc01d05bb6
2 changed files with 7 additions and 5 deletions

View File

@@ -529,7 +529,7 @@
// Above this temperature the heater will be switched off.
// This can protect components from overheating, but NOT from shorts and failures.
// (Use MINTEMP for thermistor short/failure protection.)
#define HEATER_0_MAXTEMP 275
#define HEATER_0_MAXTEMP 300
#define HEATER_1_MAXTEMP 275
#define HEATER_2_MAXTEMP 275
#define HEATER_3_MAXTEMP 275

View File

@@ -1224,7 +1224,7 @@ void AnycubicTouchscreenClass::CheckSDCardChange()
void AnycubicTouchscreenClass::CheckHeaterError()
{
if ((thermalManager.degHotend(0) < 5) || (thermalManager.degHotend(0) > 290))
if ((thermalManager.degHotend(0) < 5) || (thermalManager.degHotend(0) > 300))
{
if (HeaterCheckCount > 60000)
{
@@ -1743,8 +1743,10 @@ void AnycubicTouchscreenClass::GetCommandFromTFT()
unsigned int tempvalue;
if (CodeSeen('S'))
{
tempvalue = constrain(CodeValue(), 0, 275);
thermalManager.setTargetHotend(tempvalue, 0);
tempvalue = constrain(CodeValue(), 0, 260);
if(thermalManager.degTargetHotend(0) <= 260) {
thermalManager.setTargetHotend(tempvalue, 0); // do not set Temp from TFT if it is set via gcode
}
}
else if ((CodeSeen('C')) && (!planner.movesplanned()))
{
@@ -1752,7 +1754,7 @@ void AnycubicTouchscreenClass::GetCommandFromTFT()
{
queue.inject_P(PSTR("G1 Z10")); //RASE Z AXIS
}
tempvalue = constrain(CodeValue(), 0, 275);
tempvalue = constrain(CodeValue(), 0, 260);
thermalManager.setTargetHotend(tempvalue, 0);
}
}