Due to EMI some machines might experience false endstop triggers when homing. By reducing the endstop_poll_count to two samples, we are closely matching the behaviour of Marlin 1.1.8 and earlier.
Hopefully fixing issue #8 for good.
Other updates:
- Enabling printcounter, show statistics using the M78 command
Co-Authored-By: notching <notching@users.noreply.github.com>
Co-Authored-By: md66pt <md66pt@users.noreply.github.com>
While adding ENDSTOP_NOISE_FILTER, I try to reduce the impact on accuracy as much as possible by reducing the endstop_poll_count to 2.
Possible fix for #8.
Thanks to @notching, @mensikv and @md66pt for the valuable feedback!
Thanks to feedback from @DerDominik I was made aware that Anycubic's default acceleration values in their source code are different from the ones they use in their compiled firmwares. Seems like insufficient torque on the Y-axis caused step loss on TMC2208 for that reason.
Co-Authored-By: DerDominik <derdominik@users.noreply.github.com>
Thanks to some great feedback from @RolandRosenfeld I did some small tweaks:
- Adjusted auto PID tune parameters
- Replaced manufacturer PID values
- Minor changes to the readme
- Raised retraction on G26 Mesh Test
- Merged latest bugfix from derhopp
- Added latest hex files
Co-Authored-By: Roland Rosenfeld <roland@spinnaker.de>
To further optimize print quality even at very high speeds (I aim for roughly 80-100mm/s), I enabled S_CURVE_ACCELERATION and tweaked the jerk and default acceleration values.
Note: This is still in testing. As soon as I finish and it works as I like, I'll push it onto the master branch. If you see this commit on the master branch, it's safe to flash.
Since a custom fan duct caused the heat block on my printer to cool down enough to have a negative impact on PETG printing, I adjusted the auto PID tune aswell as the default PID values.
Also adding a precompiled hex file of all the previous changes.
• Added auto PID tune of heatbed to the special TFT menu
•Enabled automatic saving on both PID tune commands
• Added preheating and mesh leveling commands to the special TFT menu
• Mentioned changes in readme
After getting my extruder to work reliably on a Vref of 1.100V on the TMC2208, I had to adjust my e-steps quite a bit from the original value from Anycubic. Assuming you have a TMC2208 on a similar voltage, this might work well right after flashing, calibrating your e-steps is recommended in any case.