Some hosts like Pronterface use continuous M105 commands to poll temperature, this causes a software halt when the heating via M109 or M190 is finished. Flushing the rx buffer fixes this.
As reported in #15, thanks to @rug156 for the feedback!
As a possible fix for the bug with Cura's end Gcode as described in
issue #7, I changed the leveling state to be disabled after homing since
Cura uses X homing in their end Gcode.
Due to EMI some machines might experience false endstop triggers when homing. By reducing the endstop_poll_count to two samples, we are closely matching the behaviour of Marlin 1.1.8 and earlier.
Hopefully fixing issue #8 for good.
Other updates:
- Enabling printcounter, show statistics using the M78 command
Co-Authored-By: notching <notching@users.noreply.github.com>
Co-Authored-By: md66pt <md66pt@users.noreply.github.com>
While adding ENDSTOP_NOISE_FILTER, I try to reduce the impact on accuracy as much as possible by reducing the endstop_poll_count to 2.
Possible fix for #8.
Thanks to @notching, @mensikv and @md66pt for the valuable feedback!
Thanks to feedback from @DerDominik I was made aware that Anycubic's default acceleration values in their source code are different from the ones they use in their compiled firmwares. Seems like insufficient torque on the Y-axis caused step loss on TMC2208 for that reason.
Co-Authored-By: DerDominik <derdominik@users.noreply.github.com>
Thanks to some great feedback from @RolandRosenfeld I did some small tweaks:
- Adjusted auto PID tune parameters
- Replaced manufacturer PID values
- Minor changes to the readme
- Raised retraction on G26 Mesh Test
- Merged latest bugfix from derhopp
- Added latest hex files
Co-Authored-By: Roland Rosenfeld <roland@spinnaker.de>